Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Cancers (Basel) ; 16(6)2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38539565

RESUMO

The spectral quality of magnetic resonance spectroscopic imaging (MRSI) can be affected by strong magnetic field inhomogeneities, posing a challenge for 3D-MRSI's widespread clinical use with standard scanner-equipped 2nd-order shim coils. To overcome this, we designed an empirical unified shim-RF head coil (32-ch RF receive and 51-ch shim) for 3D-MRSI improvement. We compared its shimming performance and 3D-MRSI brain coverages against the standard scanner shim (2nd-order spherical harmonic (SH) shim coils) and integrated parallel reception, excitation, and shimming (iPRES) 32-ch AC/DC head coil. We also simulated a theoretical 3rd-, 4th-, and 5th-order SH shim as a benchmark to assess the UNIfied shim-RF coil (UNIC) improvements. In this preliminary study, the whole-brain coverage was simulated by using B0 field maps of twenty-four healthy human subjects (n = 24). Our results demonstrated that UNIC substantially improves brain field homogeneity, reducing whole-brain frequency standard deviations by 27% compared to the standard 2nd-order scanner shim and 17% compared to the iPRES shim. Moreover, UNIC enhances whole-brain coverage of 3D-MRSI by up to 34% compared to the standard 2nd-order scanner shim and up to 13% compared to the iPRES shim. UNIC markedly increases coverage in the prefrontal cortex by 147% and 47% and in the medial temporal lobe and temporal pole by 29% and 13%, respectively, at voxel resolutions of 1.4 cc and 0.09 cc for 3D-MRSI. Furthermore, UNIC effectively reduces variations in shim quality and brain coverage among different subjects compared to scanner shim and iPRES shim. Anticipated advancements in higher-order shimming (beyond 6th order) are expected via optimized designs using dimensionality reduction methods.

2.
Magn Reson Med ; 86(6): 3182-3191, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34309072

RESUMO

PURPOSE: To develop a single-scan method for B1+ -corrected T1 mapping and apply it for free-breathing (FB) cardiac MR multitasking without electrocardiogram (ECG) triggering. METHODS: One dual flip-angle (2FA) inversion recovery (IR)-FLASH scan provides two observations of T1∗ (apparent T1 ) corresponding to two distinct combinations of the nominal FA α and B1+ . Spatiotemporally coregistered T1 and B1+ spin history maps are obtained by fitting the 2FA signal model. T1 estimate accuracy and repeatability for single flip-angle (1FA) and 2FA IR-FLASH sequence MR multitasking were evaluated at 3T. A T1 phantom was first imaged on the scanner table, then on two human subjects' thoraxes in both breath-hold (BH) and FB conditions. IR-turbo spin echo (IR-TSE) static phantom T1 measurements served as reference. In 10 healthy subjects, myocardial T1 was evaluated with ECG-free, FB multitasking sequences alongside ECG-triggered BH MOLLI. RESULTS: For phantom-on-table T1 estimates, 2FA agreed better with IR-TSE (intraclass correlation coefficient [ICC] = 0.996, mean error ± SD = -1.6% ± 1.9%) than did 1FA (ICC = 0.922; mean error ± SD = -4.3% ± 12%). For phantom-on-thorax, 2FA was more repeatable and robust to respiration than 1FA (coefficient of variation [CoV] = 1.2% 2FA, = 11.3% 1FA). In vivo, in intrasession T1 repeatability, 2FA (septal CoV = 2.4%, six-segment CoV = 4.4%) outperformed 1FA (septal CoV = 3.1%, six-segment CoV = 5.5%). In six-segment T1 homogeneity, 2FA (CoV = 7.9%) also outperformed 1FA (CoV = 11.1%). CONCLUSION: The 2FA IR-FLASH improves T1 estimate accuracy and repeatability over 1FA IR-FLASH, and enables single-scan B1+ -corrected T1 mapping without BHs or ECG when used with MR multitasking.


Assuntos
Interpretação de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Humanos , Espectroscopia de Ressonância Magnética , Miocárdio , Imagens de Fantasmas , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...